Multiple keyboards and mice take up more than just extra space, they make working a little more complicated. Already a member? Reply 0 0 Titomahawk Top Student Posts: 6 Member Since: ‎08-12-2009 Message 6 of 16 (22,266 Views) Report Inappropriate Content Re: ProLiant ML350 G6 power problem Options Mark as New Bookmark Learn More Red Hat Product Security Center Engage with our Red Hat Product Security team, access security updates, and ensure your environments are not exposed to any known security vulnerabilities. his comment is here

These new servers will shut off at a minimal fluctuation in voltage, fluctuations that are not noticeable to the eye or noticeable to other servers and PCs. All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission. Edited Jan 11, 2016 at 2:33 UTC 2 Pimiento OP coreycavenaugh Jan 11, 2016 at 3:02 UTC 1) I didn't see a reason for them to not be It is strange because I have 3 other servers connected to the same ups and they all work fine but somehow this particular server gets restarted.

Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small Thank you! Register · Log In HP Support Forum Home > Desktops > Hardware > ProLiant ML350 G6 power problem HP Support Forums Join in the conversation. Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL Technology has not only changed the behavior and the expe… Hardware Components Sennheiser Wireless Hardware How to change your primary email address Video by: Kyle Hi everyone!

Reply 0 0 sanillad Student Posts: 1 Member Since: ‎02-25-2010 Message 10 of 16 (21,819 Views) Report Inappropriate Content Re: ProLiant ML350 G6 power problem Options Mark as New Bookmark Subscribe Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking server has stayed up for 2 weeks now. Open Source Communities Comments Helpful Follow Why system throws "System Power Supply: General Failure (Power Supply X)" messages ?

so test all parts first - you may have more than 1 bad device... 0 Write Comment First Name Please enter a first name Last Name Please enter a last name Community ProLiant Servers (ML,DL,SL) CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as Join our community for more solutions or to ask questions. http://www.tek-tips.com/viewthread.cfm?qid=818144 Power up the server.

After i restarted the server (nothing wrong with the booting of Windows 2003 32 R2 Standard Edition), system log shows 2 errors:First one is: POST Error 1615-Power supply failure or Power I am new to dealing with this server as I just joined this company and started my first week as their IT Manager. ML350G5 System Power Supply: General Failure (Powe... MenuExperts Exchange Browse BackBrowse Topics Open Questions Open Projects Solutions Members Articles Videos Courses Contribute Products BackProducts Gigs Live Careers Vendor Services Groups Website Testing Store Headlines Ask a Question Ask

Featured Post How your wiki can always stay up-to-date Promoted by Quip, Inc Quip doubles as a “living” wiki and a project management tool that evolves with your organization. http://systemmanager.ru/c00724721.en/21076.htm HP Support Center (английский) 2. Центр технической по... Коды ошибок HP LaserJet Professional M1130/M1210 Коды ошибок M1132mfp и M1210mfp: E 0 - замятие бумаги E 1 - нет бумаги E 2 Thanks to all for input that helped me solve this. Add Stickiness To Your Site By Linking To This Professionally Managed Technical Forum.Just copy and paste the BBCode HTML Markdown MediaWiki reStructuredText code below into your site. HP (Compaq) servers

When i check the logs i see this message :POST Error:1615-Power Supply Failure or Power Supply Unplugged in Bay 2I have tried removing one of the power supplies and even interchanging this content The DL380G5 uses the iLO2, the current firmware for that is 1.82 or 2.00If you try to force the older iLO's firmware, the iLO2 will reject it. Replace the new power supply in bay 1. Is it cause by the firmware need to upgrade or power surge.Any idea?Regards,Chui 0 Kudos Reply Trygve Henriksen Respected Contributor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight

Explore Labs Configuration Deployment Troubleshooting Security Additional Tools Red Hat Access plug-ins Red Hat Satellite Certificate Tool Red Hat Insights Increase visibility into IT operations to detect and resolve technical issues Reply 0 Reply 0 0 RoyalSerpent Associate Professor Posts: 1,250 Member Since: ‎01-27-2009 Message 2 of 16 (23,263 Views) Report Inappropriate Content Re: ProLiant ML350 G6 power problem Options Mark as Since the other PCs could get by with the existinglag time of the UPS, we must focus on the PSU inside the HP.You could pull the plug from the wall and weblink The last time I had a DIMM error the log told me which DIMM it was, but I am lost on this one.

Use a power inverter of appropriate current rating to convert the +12VDC battery power to230 AC.Suspect what you have is a cheap standby UPS. As of right now, the errors that I received were:  1615-Power supply failure or Power supply unplugged in bay 1 1794-Drive Array - Array Accelerator Battery Charge Low      Battery I did plug it in which currently has the server online and it has remained that way since I reported this issue.

Reply 0 0 dwh Top Student Posts: 9 Member Since: ‎01-29-2010 Message 7 of 16 (22,226 Views) Report Inappropriate Content Re: ProLiant ML350 G6 power problem Options Mark as New Bookmark

Bay 1 led is off. Are you aComputer / IT professional?Join Tek-Tips Forums! A quality PSU should have sufficient reserve capacity on the primary caps to maintain power for a smooth transition to the UPS. Conferences, collaborative groups, flexible seating and working from home require a new level of mobility.

If you're looking for how to monitor bandwidth using netflow or packet s… Network Analysis Networking Network Management Paessler Network Operations Advertise Here 737 members asked questions and received personalized solutions Library Lab Refresh Our library lab needed some clean up and refreshing. Insert it into bay 1. check over here The BBWC battery has failed, that's a separate problem. 0 Pimiento OP antonioraimundo Jan 11, 2016 at 11:18 UTC Hi,  That Proliant Generation has Ilo2, login into it

Connect with top rated Experts 21 Experts available now in Live! Join the community of 500,000 technology professionals and ask your questions. My #1 power supply is connected to utility power with surge protection, and the #2 power supply is on the Eaton UPS. Comment Submit Your Comment By clicking you are agreeing to Experts Exchange's Terms of Use.

Close Reply To This Thread Posting in the Tek-Tips forums is a member-only feature. One thing that you can do, is buying a spare machine like that one online, they are very cheap and it will give parts and piece of mind while you adapt Reply 0 0 Titomahawk Top Student Posts: 6 Member Since: ‎08-12-2009 Message 3 of 16 (23,253 Views) Report Inappropriate Content Re: ProLiant ML350 G6 power problem Options Mark as New Bookmark Shutdown the server again.

Reply 0 0 dwh Top Student Posts: 9 Member Since: ‎01-29-2010 Message 8 of 16 (22,212 Views) Report Inappropriate Content Re: ProLiant ML350 G6 power problem Options Mark as New Bookmark Can anyone tell me what Module: 255 and Slot: 255 mean? I tried putting in a spare power supply but was still getting the same issues.I ended up replacing the power control board and then was able to get a temperature reading, I see, that the PPM light is on, so this module may be defective.

We Acted. However, the second power plug that I added to the server is not plugged into the UPS. HomeChange ViewPrint 1615-Power Supply Configuration Error - A working power supply must be installed in Bay 1 for proper cooling. - System Halted!