Home > Post Error > Post Error 1719

Post Error 1719

In our testing, applying the recommended firmware on servers with this configuration will cause the server to freeze at post. Join Now Recently I acquired two brand spanking new DL380 G9 servers. I understand your frustration at what happened. if that does not work, ask them to replace the controller ...  0 Datil OP [email protected] May 2, 2015 at 1:53 UTC Brand Representative for HP @Pctaco, thank his comment is here

I remembered that I took pictures of the monitor when the server locked-up last time; I'll attach the ESX messages here. 364275.jpg ‏476 KB 0 Kudos Reply Simon.H Advisor Options Mark They are now sending me a new power supply and apparently think this will solve my issue. We had a couple Netgear 10Gbe switches (for a cheapo VMware VSAN deployment) that wouldn't save configs after a reboot. Very helpful Somewhat helpful Not helpful End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c01917689&sp4ts.oid=1157688

They refused to escalate the issue until a packet capture was handed over. One of our engineers ended arguing with someone on the phone for a couple of hours, repeatedly trying to explain that a packet capture wouldn't matter, because literally nothing was hooked Re: HP ProLiant Gen9 Advisory - SmartArray Firmware Update FinnurGudmundssonISB Oct 11, 2015 9:55 AM (in response to kevo12) We were hit by this flaw on the only BL460c G9 we The information in this document is subject to change without notice.

Anyone with a solution? 0 Kudos Reply BrightMinds Frequent Advisor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎11-11-2010 09:05 Edited May 2, 2015 at 10:24 UTC Tags: PctacoJalapeno 2 Cayenne OP brandonwardlaw May 2, 2015 at 7:25 UTC Synchronet is an IT service provider. Learn more about Red Hat subscriptions Product(s) Red Hat Enterprise Linux Category Upgrade Tags hardware kernel Quick Links Downloads Subscriptions Support Cases Customer Service Product Documentation Help Contact Us Log-in Assistance Need access to an account?If your company has an existing Red Hat account, your organization administrator can grant you access.

The system returned: (22) Invalid argument The remote host or network may be down. We Acted. Last option I would also consider is the backplane that the HDD's plug into and on the other side the SAS cables plug into it. https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/Absolute-nightmare-of-a-DL380-G7/td-p/4709685 Pctaco wrote:brandonwardlaw wrote: Really could be worse.

Updating the P440 firmware alone caused our system to not POSTthanks,Kev Like Show 0 Likes (0) Actions Go to original post Actions Remove from profile Feature on your profile More Like Solution Unverified - Updated 2014-01-01T03:29:40+00:00 - English No translations currently exist. It's all a process of elimination. End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to select your country ArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisČeská republikaChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMagyarországMéxicoNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto

Might be worth opening the server and reseating the cards, memory, etc, anything that won't void the warranty. http://h20564.www2.hp.com/hpsc/doc/public/display?docId=mmr_kc-0108397&sp4ts.oid=3182561 No array errors. It's all a process of elimination. Immediate crash.

Sign-in Register Site help Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure this content We had a couple Netgear 10Gbe switches (for a cheapo VMware VSAN deployment) that wouldn't save configs after a reboot. As in has an "i" at the end of the model. Release Date: 2016-02-16 Last Updated: 2016-02-16 DESCRIPTION Document Version Release Date Details 6 02/12/2016 Updated with a Note in the Resolution. 5 01/08/2016 Updated the Resolution with Firmware Version 3.56. 4

Text Quote Post |Replace Attachment Add link Text to display: Where should this link go? They spend two weeks and come back with this error, which was generated because the first power supply was not plugged in (I was out of clean power ports and waiting NAVIGATION TIP : For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to the Navigation Tips document . weblink Really could be worse.

Please try the following:Use a different search stringIf search was based on document ID, check document ID or switch to keyword search Change your search criteria selectionCheck your search string for End of contentUnited StatesHP WorldwideStart of Country / Region Selector contentSelect Your Country/Region and LanguageClick or use the tab key to select your countryArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisČeská republikaChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMagyarországMéxicoNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto RicoSchweizSouth AfricaSuisseTürkiyeUnited KingdomUnited StatesUruguayVenezuelaΕλλάδαРоссия中国台灣日本香港대한민국End of Thank you!

Config: dual quad-core, 24GB ram, 4x146GB SAS 15k, 2x 300GB SAS 10k.

Re: HP ProLiant Gen9 Advisory - SmartArray Firmware Update kevo12 Oct 26, 2015 12:31 PM (in response to kevo12) Just a follow-up here..The issue was isolated to the SmartArray P440 with The information provided is provided "as is" without warranty of any kind. We had the Linux guys perform the upgrade on there server and although it appears to have applied successfully, the firmware version never changed to 3.02. Open Source Communities Comments Helpful 3 Follow Why system rebooted after message "POST error 1719 : A controller failure event occurred prior to this power-up" ?

Doing these steps did get the server back online. If you've done the FW as you say, then its time to start ruling out components. If its orange, the part is refurbished, if it's yellow, it is a new part. http://ismymailsecure.com/post-error/post-error-message-1719.html [email protected] might be able to help you out.  Tags: [email protected] 6 Mace OP Denis Kelley May 1, 2015 at 7:52 UTC 2 weeks is kind of silly.

SCOPE Any of the following Smart Array Controllers or Host Bus Adapters supported by HP ProLiant Gen9 servers: HP H240 Smart Host Bus Adapter HP H241 Smart Host Bus Adapter HP We use original HP ups's and APC Symetra PX ups's.It seem high quality HP PSU require really good online ups.Why do blame HP? Also, have you tried removing and re-inserting the controller and cables? What's the spec of your G7?

If you've done the FW as you say, then its time to start ruling out components. How do I get in contact with someone who both speaks English and has better computer skills than my grandmother? Hardware Platforms Affected: HP ProLiant DL380p Gen8 Server, HP ProLiant ML350e Gen8 Server, HP ProLiant SL210t Gen8 Server, HP ProLiant SL250s Gen8 Server, HP ProLiant SL270s Gen8 SE Server, HPE Integrated I've now disabled the write cache on the array controller for that server to see if it still re-occurs.

Then, after reboot, I get the same RAID errors as you guys get: POST Message 10/30/2010 19:37 10/30/2010 19:32 2 POST Error: 1719 - A controller failure event occurred prior to Tags: [email protected] 2 Tabasco OP Kev840 May 1, 2015 at 7:53 UTC +100 for Priscilla, she's the bomb!  Helped me get lots of stuff resolved in a jiffy. This was only offered as a default option on the G7's so I wonder if it is related to the problem... I had been planning on running some prime95 torture tests on this equipment to find out of it was an array controller or a processor problem.

Share This Page Legend Correct Answers - 10 points These products are now supported by Hewlett Packard Enterprise. SUPPORT COMMUNICATION - CUSTOMER ADVISORY Document ID: c04805565 Version: 6 Advisory: (Revision) HP ProLiant Gen9 Servers - The Server May Stop Responding and Will Display Power-On Self-Test (POST) Error Messages on By creating an account, you're agreeing to our Terms of Use and our Privacy Policy Not a member?

Current Customers and Partners Log in for full access Log In New to Red Hat? Edited May 1, 2015 at 8:32 UTC Tags: HP358,772 FollowersFollow Reply Subscribe View Best Answer RELATED TOPICS: how to fix "suspicious" hp msm765 It's official: HP will break itself in two The fix was to update both the SmartArray and the Expander card firmware at the same time. Netgear support was insistent that they needed a packet capture uploaded before they would look at the issue/try to find a root cause.

i.e. You may get a better answer to your question by starting a new discussion.