Home > Post Error > Post Error 1779 Drive

Post Error 1779 Drive

A thing to mention: the amber light and the error-messages may be also present AFTER replacement of the bad drive - this only means that you do not have full redundancy Restore your data... which is how I found it this morning.   The guy from HP said that these problems did not happen very often, maybe twice per year. Get 1:1 Help Now Advertise Here Enjoyed your answer? his comment is here

When you brought up the system with your old drives, you should have again deleted the new data logical drive either in the BIOS raid utility or with the Smartstart/DL180 Setup Meaning, the power to the drives should never be removed if the Smart Array controller is powered on. What's the difference between A and AAAA DNS records? But I think it could be useful for other people using HP RAID controllers.

You may get a better answer to your question by starting a new discussion. share|improve this answer answered Feb 6 '11 at 0:05 Nic 7,135124084 add a comment| up vote 0 down vote If not, which RAID controllers support this, so I know what to This w… Storage Windows 8 Advertise Here 737 members asked questions and received personalized solutions in the past 7 days. Run Array Diagnostics Utility (ADU) if previous positions are unknown.

The drives also need some firmware updates.Drive 4 shows the last failure reason as "hot removed" which is probably when you pulled it, so that's to be expected, but drive 3 it's a RAID 5, it should go into recovery mode when the old drive is unplugged and it should start recovering the parity onto the new drive.That's a lot of "should", Unable to rebuild array. Insert your new drives.

Again, sincere thanks. 0 Mace OP Huw3481 Nov 4, 2013 at 4:02 UTC HD IT Solutions is an IT service provider. The story so far... if (λ x . navigate to this website Provide feedback Please rate the information on this page to help us improve our content.

Equally thanks to Spiceworks and the community have made a new contact in Huw who works close to where I am based. Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking Is unpaid job possible? I'd take the hit, let the server boot and back it up if it was me.

What's the drive that you use for replacement?Thanksregards, How to Say Thank You? this page So, the user reset the system and saw the following messages: Slot 2 HP Smart Array P812 Controller 1 Logical Drive 1779-Slot 2 Drive Array - Replacement drive(s) detected OR previously Any one know of any good reliable data recovery companies in the UK, preferably East Midlands / South Yorkshire etc? Can anyone shed some light on this please?CheersJason Tags: error 640006POST Error 1779 View All (2) ADUReport.txt ‏1012 KB 0 Kudos Reply All Forum Topics Previous Topic Next Topic 10 REPLIES

It shouldn't do that on a RAID 5. http://ismymailsecure.com/post-error/post-error-1784-drive-array-drive-failure.html I still have faith in the product, am desperately pleased we have support in place with yourselves until 2015 and am quite happy to put this down to experience. The backup is showing as being successful but I am nervous to say the least. I am contacting HP support to see if under warranty.

We have written the day off business wise so another few hours will not do much harm I suppose!   0 Mace OP Huw3481 Nov 4, 2013 at Apologies! 0 Mace OP Best Answer Huw3481 Nov 4, 2013 at 3:35 UTC HD IT Solutions is an IT service provider. When powering down the system, the server must be powered down before powering down any external storage systems. 1783-Slot X Drive Array Controller Failure Audible Beeps: None Possible Cause: Controller failed. weblink Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small

Subscribe to our monthly newsletter for tech news and trends Membership How it Works Gigs Live Careers Plans and Pricing For Business Become an Expert Resource Center About Us Who We iLO shows POST Error: 1779-Drive Array Controller Detects Replacement Drives. Text Quote Post |Replace Attachment Add link Text to display: Where should this link go?

troubleshooting guidepage 1................................................................................................................................................................

I had assumed that the RAID metadata stored on the disks would be sufficient to bring the old RAID array back online, but that doesn't seem to be the case. These products are now supported by HP Inc. I've had great experiences with 3ware controllers in situations like this. Generated Mon, 24 Oct 2016 10:41:56 GMT by s_wx1157 (squid/3.5.20)

Remove the old drives. Seems odd.  Even if one drive is gone, the array should still be working. How do you say "you all" in Esperanto? http://ismymailsecure.com/post-error/post-error-1779.html Ok, but does it still show the array as being 1+0?

Your cache administrator is webmaster. Sometimes your flash drive may have issues carrying files so this will completely restore it to manufacturing settings. As they are hot-pluggable, the RAID array rebuild should start shortly after the replacement. If the problem persists, replace the array controller. 3. 1783-Intelligent Drive Array Controller Failure Audible Beeps: None Possible Cause: Integrated array controller firmware is corrupt, or the controller failed.

Print This PagePrint ShareShare Url of this page: HTML Link: Bookmark Manuals Brands HP Manuals Printer ProLight Server Troubleshooting manual HP ProLight Server Troubleshooting Manual Page 119 Hewlett-packard proliant servers troubleshooting Amber drive is obviously the one showing a failure. 0 Mace OP Huw3481 Nov 4, 2013 at 3:13 UTC HD IT Solutions is an IT service provider. Previous company name is ISIS, how to list on CV? The following process was used: Shut down server Remove drives used in data array and hot spare, and label with their positions.

Join Now For immediate help use Live now! What Our Users Say Press & Media Contacts Advertising DMCA Policy Brands × Login Login to ManualsLib Don't have an account? Array A says RAID 1, Array B says RAID 5.Update those firmwares (you'll need to reboot) and then see how things look. Find the super palindromes!

Once in the OS, I was able to access the Array Configuration Utility to "delete" the RAID10 configuration. more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed I guess the prudent thing to do would be stick the new drive in first and take it from there? Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL

Email Reset Password Cancel Need to recover your Spiceworks IT Desktop password? How to prove that a paper published with a particular English transliteration of my Russian name is mine? The E200 controller was still expecting to see the drives from the RAID10 array. Everything seems to be running OK, so regarding replacing it, do I just take out the bad drive and pop the new one in?

The system returned: (22) Invalid argument The remote host or network may be down. Very helpful Somewhat helpful Not helpful End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to