The time now is 04:40 AM. Join the community Back I agree Powerful tools you need, all for free. Reply With Quote August 7th, 2001,12:21 AM #2 robwes View Profile View Forum Posts Visit Homepage Virtual Intern Join Date May 2000 Location Tampa, FL Posts 474 Welcome to Virtualdr It Sign up! http://ismymailsecure.com/post-error/post-error-1784-drive-array-drive-failure.html

We have written the day off business wise so another few hours will not do much harm I suppose!   0 Mace OP Huw3481 Nov 4, 2013 at The HP Model number for the drives is DG072A8B54 Recently, one of the two drives appear to have failed, and is no longer detected. And if we can't, I suppose, with the striping, depending on the stripe size would you be able to get small chunks? Show all Bl35p Bl40p Bl460c Bl480c Bl680c g5 Dl560 Dl590/64 Dl740 Ml310 Ml330 Ml570 Comments to this Manuals Your Name Enter your comment: Symbols: 0 Enter text from picture: Write a see it here

Diagnostic flowchartspage 19................................................................................................................................................................ HP websitepage 69................................................................................................................................................................ My understanding is that in general enterprise drives are more prone to simply reporting as fatal, rather than returning possibly corrupt data. Join Now Hi all, Came into work this morning to find my HP ML330 (main server running as file server and CRM for the business) was stuck in a boot cycle

Any one know of any good reliable data recovery companies in the UK, preferably East Midlands / South Yorkshire etc? See more RELATED PROJECTS System Admin of Mid-sized Network I am the Sys Admin to a mid-sized multi-faceted network. Your faith in the product and the support team is much appreciated.  Lucky, lucky you....to be so near to the remarkable expert Huw.  As you are aware, his knowledge if HP Powered by vBulletin Version 4.2.2 Copyright © 2016 vBulletin Solutions, Inc.

It says that disk 2 is faulty.   A chap from Data Recovery suggested that depsite other 3 drives showing OK, chances are we have got multiple drive failures - hence Drive Failed Logical Drive   1 2 Next ► 30 Replies Mace OP Huw3481 Nov 4, 2013 at 1:51 UTC HD IT Solutions is an IT service provider. TECHNOLOGY IN THIS DISCUSSION HP 358772 Followers Follow Hewlet Packard Join the Community! I guess the prudent thing to do would be stick the new drive in first and take it from there?

I have a SATA-to-USB adapter, I know the physical adapter is the same for SAS, but I'm guessing this won't actually work for connecting to a SAS drive. Please try the following:Use a different search stringIf search was based on document ID, check document ID or switch to keyword search Change your search criteria selectionCheck your search string for It should stay up. The array may just auto-rebuild itself.

The Following SCSI Drive(s) Should Be Replaced: SCSI Port Y: SCSI ID Z Audible Beeps: None Possible Cause: Defective drive or SCSI cables detected. this If the problem persists, replace the controller. 2. 1784-Slot X Array Controller is in lock-up state due to a hardware configuration failure. (Controller is disabled until this problem is resolved.) Audible Is unpaid job possible? If drives have not been replaced, this message indicates an intermittent drive failure.

See, it's the non-system disk error that worries me.  The server isn't seeing anything it can boot from. this content Thank you.     0 Anaheim OP Craig G UK Nov 4, 2013 at 2:16 UTC Hi,   When I access the array config via f8 it says There are also various "\device\harddisk3\dr3 has a bad block" errors within the eventlog. So if the data is important -> don't touch them anymore and call an recovery expert. –frupfrup Jan 21 '15 at 15:30 1 RAID0 usually means 0 chance of data

Error messages 119 Table of Contents UncorrectableMemoryError(slotX,MemoryModuleY) HpBladesystemInfrastructureErrorCodes ServerBladeManagementModuleErrorCodes Previous page Next page 1...117118119120121 Related Manuals for HP HP ProLight Server Desktop HP BL685c - ProLiant - 4 GB RAM Phoned HP support and spent an hour going through various tests etc using the SmartStart CD. HomeChange ViewPrint 1784-Slot X Drive Array Drive Failure. weblink Use that to go in and check the status of all your hardware.

If the problem still exists and a cache memory module is attached to the controller, replace the cache memory module and reboot the server. 1784-Slot X Drive Array Drive Failure. BUT: I would't try anything with the disks for now. Each piece of data is split across the drives to improve performance, but for most files, if you loose half the data, the file is corrupted beyond usability. –SnakeDoc Jan 21

Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL

Are there any historically significant examples? Then check your cables as rowbes suggested. Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking Connections between Complexity Theory & Set Theory Does the code terminate?

i.e. Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small asked 1 year ago viewed 1678 times active 1 year ago Related 3Recovering data from SAS drives after failed SAS Controller Card?5Identify HP Array Logical Drive From Windows0HP B110i controller not http://ismymailsecure.com/post-error/post-error-1797-drive-array-array-accelerator-read-error-occurred.html I still have faith in the product, am desperately pleased we have support in place with yourselves until 2015 and am quite happy to put this down to experience.

Error using ConTeXt subsub module, TexLive, FreeBSD Counterintuitive polarizing filters Asking for a written form filled in ALL CAPS Can a bike computer be used on the rear wheel? To start viewing messages, select the forum that you want to visit from the selection below. A word to describe meaningless exchanges in conversation Teaching a blind student MATLAB programming Why are planets not crushed by gravity? Plus the HP guy never even mentioned this line of repair, so it makes me a bit twitchy.

Both the hard drive and motherboard can be pretty spendy on a laptop. By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner Any ideas?7HP SmartArray P400: How to repair failed logical drive?1HP P410i Array Controller and lost logical Drive3HP DL380 G5 Predictive failure of a new drive1How to replace failed drive in RAID Do you get the F8 prompt on boot to go into the array config?

Thank you!   Reply Subscribe View Best Answer RELATED TOPICS: RAID 5 failure on logical drive- what to do? With any luck, it will just be a matter of pulling out the bad disk, and sticking in a new one. By creating an account, you're agreeing to our Terms of Use and our Privacy Policy Not a member? And we were the (un)lucky winners!      0 Mace OP Huw3481 Nov 4, 2013 at 2:57 UTC HD IT Solutions is an IT service provider.

Hang on, you're getting a 1769 error on POST?   0 Mace OP Huw3481 Nov 4, 2013 at 3:28 UTC HD IT Solutions is an IT service provider. Results 1 to 3 of 3 Thread: 1784 disk controller failure Tweet Thread Tools Show Printable Version Email this Page… Subscribe to this Thread… Search Thread Advanced Search Display Linear At this point it goes no further.Apon more investivation in the iLO the following errors are reported: POST Error: 1784-Drive Array Drive FailurePOST Error: 1789-Drive Not Responding, Physical DriveI've tried removing Apologies! 0 Mace OP Best Answer Huw3481 Nov 4, 2013 at 3:35 UTC HD IT Solutions is an IT service provider.

They do come loose, because hard drives vibrate. Reseat the controller in the PCI slot. 2. The backup is showing as being successful but I am nervous to say the least.