The failed drive will not be rebuilt and the system will continue to operate in a failed state of Interim Data Recovery Mode. • If drive recovery is not successful, run does the disk management in the Proliant utilities see the new drive? I am visiting the client tonight. End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to select your country ArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisČeská republikaChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMagyarországMéxicoNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto his comment is here

The operating System is Windows 2008 R2 and is still functional (its serving its purpose). Action: Be sure all cables are connected properly and securely. 1. What Our Users Say Press & Media Contacts Advertising DMCA Policy Brands × Login Login to ManualsLib Don't have an account? Select F1 to continue – drive array will remain disabled. view publisher site

Browse other questions tagged hp hp-proliant hardware-raid raid5 hp-smart-array or ask your own question. Select F2 to reset configuration – all data will be lost. If the rebuild was aborted due to a read error from another physical drive in the array, back up all readable data on the array, run ADU, and then restore the It should be viewed in landscape mode.I hope this helps.Brian 286713.doc ‏679 KB 0 Kudos Reply The opinions expressed above are the personal opinions of the authors, not of Hewlett Packard

This message is displayed if the F2 key was pressed during a previous boot or if the F1 key was pressed during a previous boot and the system rebooted before the How do fix this? Action: Perform one of the suggested actions: Press the F1 key to retry Automatic Data Recovery to the drive. There's a high-likelihood that this is the result of read errors on the remaining drives in the RAID 5 array. –ewwhite Jan 6 '13 at 21:46 add a comment| Your Answer

more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner There is a HP Utility Array Configuration Utility which was installed to see the RAID configuration from the OS. https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/POST-Error-1787/td-p/2619708 Your cache administrator is webmaster.

Action: • If replacement drives are installed in the wrong bays, properly reinstall the drives as indicated and: • Press the F1 key to restart the server with the drive array Restore password × Upload manual upload from disk upload from url Thank you for your help! Port 85 codes and iLO messagespage 131................................................................................................................................................................ Action: If replacement drives are installed in the wrong bays, properly reinstall the drives as indicated and: Press the F1 key to restart the server with the drive array disabled.

I admit I should have ideally set the hot spares when the array was created - am now learning the hard way. https://h20628.www2.hp.com/km-ext/content-webapp/document?docId=emr_na-c02735164 Does using Mold Earth to trip someone break its rule against causing damage? This thread has been moevdfrom Storage > General to ProLiant Servers (ML,DL,SL). - Hp Forum Moderator 0 Kudos Reply All Forum Topics Previous Topic Next Topic 4 REPLIES Greg Carlson Honored Any feedback would be welcome.

Generated Mon, 24 Oct 2016 10:40:58 GMT by s_wx1011 (squid/3.5.20) this content Show that the vector space of all continuous real-valued functions is infinite-dimensional DDoS ignorant newbie question: Why not block originating IP addresses? The Following SCSI Drive(s) Should Be Replaced: SCSI Port Y: SCSI ID Z ビープ音 なし 考えられる原因 ドライブまたはSCSIケーブルの障害が検出されました。 対処方法 すべてのケーブルが正しくしかもしっかりと接続されていることを確認します。 すべてのドライブが確実に固定されていることを確認します。 障害のあるケーブル、ドライブX、またはその両方を交換します。 1787-Drive Array Operating in Interim Recovery Mode... ビープ音 なし 考えられる原因 Interviewee offered code samples from current employer -- should I accept?

Please try the following:Use a different search stringIf search was based on document ID, check document ID or switch to keyword search Change your search criteria selectionCheck your search string for Replace drive X. (depending on the fault-tolerance level, all data may be lost if another drive fails). 3. 1788-Slot X Drive Array Reports Incorrect Drive Replacement... ...The following SCSI drive(s) should Audible Beeps: None Possible Cause: System is in Interim Data Recovery Mode and a failed or replacement drive has not yet been rebuilt. http://ismymailsecure.com/post-error/post-error-1787.html I have run DAAD Drive Array Advance Diagnostics and ADU Array Diagnostics Utility and both come up clean.

The two remaining drives show up as unassigned in the Array Configuration Utility. The system returned: (22) Invalid argument The remote host or network may be down. asked 3 years ago viewed 20382 times active 3 years ago Related -2Red Hat 5.3 on HP Proliant DL380 G5 and failed drive on RAID controller7HP SmartArray P400: How to repair

share|improve this answer answered Jan 6 '13 at 19:49 ewwhite 152k47301578 Thanks I will give this a go and post my results once I get them tomorrow. –user151520 Jan

When the drives were swapped, the server showed question marks for the drive that was replaced. Please try the request again. Where is the kernel documentation? I popped the failed drive out to check capacity/model, etc and when I popped it back in a restarted the server I get "invalid disk press F1 to continue".

troubleshooting guidepage 1................................................................................................................................................................ Is that correct? it's not a Compaq drive but it appears to be OK.I think if you get the drive at port1 ID4 fixed first you'll be on the right tracks. check over here port 85 codes and ilo messagespage 121................................................................................................................................................................

If the replacement drive failed, replace with another drive. These products are now supported by HP Inc. Ciao,Greg Lets Roll! 0 Kudos Reply Joe Krupiak_1 Occasional Visitor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎12-12-2003 01:03 For sanity sake I do recommend moving the drive to a physical arrangement that "matches" the logical grouping.

Audible Beeps: None Possible Cause: • Replacement drives may have been installed in the wrong drive bays. • A bad power cable connection to the drive, noise on the data cable, Please try the request again. Action: • Perform one of the suggested actions: • Press the F1 key to retry Automatic Data Recovery to the drive. Restore password × Upload manual upload from disk upload from url Thank you for your help!

What Our Users Say Press & Media Contacts Advertising DMCA Policy Brands × Login Login to ManualsLib Don't have an account? By using our site, you agree to our use of cookies. Got it, continue to print 2012-2016 ManualsLib.com About Us About ManualsLib Privacy Policy F.A.Q. Join them; it only takes a minute: Sign up Here's how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the

If the hdd was larger, it would not utilize the additional space. F1 will let the the server start but it is running slow.It's a standard system so without having access to documentation or the original PO I am assuming that it has Thesis reviewer requests update to literature review to incorporate last four years of research. If a bad power cable connection exists: ("Array Diagnostic Utility" on page 63) for more Error messages 121 Table of Contents UncorrectableMemoryError(slotX,MemoryModuleY) HpBladesystemInfrastructureErrorCodes ServerBladeManagementModuleErrorCodes Previous page Next page 1...119120121122123 Related

troubleshooting flowchartspage 17................................................................................................................................................................ How to explain the existence of just one religion? What do you call "intellectual" jobs? By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner

Hide thumbs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Antsy permutations How much interest did Sauron have in Erebor?