Home > Post Error > Post Error 1792 Hp

Post Error 1792 Hp

Beside that message everything is running OK. Power was then restored within several days, and the data in the array accelerator was flushed to the drive array. The other disks in that array are probably the same age and have the same usage and so are also likely to experience a failure. And just because your drive is new, or even refurb from the manufacturer... his comment is here

Subscribe to our monthly newsletter for tech news and trends Membership How it Works Gigs Live Careers Plans and Pricing For Business Become an Expert Resource Center About Us Who We Comment Submit Your Comment By clicking you are agreeing to Experts Exchange's Terms of Use. The array will operate at the speed of the slowest drive, and if the replacement drive is larger then the additional space will not be used. 0 Chipotle I installed them a few months ago and setup the 2nd datastore on my ESXi server but I have not placed any VMs or data at all on these drives. https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/HP-Proliant-Post-Error-1792-Drive-Array-Reports-Valid-Data-found/td-p/5294361

You'll be best to shutdown the host to replace the drive. 0 Serrano OP Payson Solutions Group Aug 2, 2010 at 3:27 UTC Payson Solutions Group is an Images and Photos Web Graphics Software How to change your primary email address Video by: Kyle Hi everyone! Connect with top rated Experts 21 Experts available now in Live! There are times, however, when those shares may disappear causing difficulty for your users.

Action: No action is required. Privacy Policy Site Map Support Terms of Use MenuExperts Exchange Browse BackBrowse Topics Open Questions Open Projects Solutions Members Articles Videos Courses Contribute Products BackProducts Gigs Live Careers Vendor Services Groups The system tells me it is rebuilding the array but when it gets to around 50% - 60% the system just reboots as if someone just pulled the plug (no blue The error in the log was ............."The description for Event ID ( 129 ) in Source ( HpCISSs2 ) cannot be found.

Join the community Back I agree Powerful tools you need, all for free. Office 365 Exchange How to Receive an eFax Video by: j2 Global Internet Business Fax to Email Made Easy - With eFax Corporate (http://www.enterprise.efax.com), you'll receive a dedicated online fax number, All rights reserved.Newsletter|Contact Us|Privacy Statement|Terms of Use|Trademarks|Site Feedback TechNet Products IT Resources Downloads Training Support Products Windows Windows Server System Center Browser   Office Office 365 Exchange Server   SQL Server https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/POST-Error-1792-Drive-Array-Reports-Valid-Data-Found-in-Array/td-p/4118034 The following information is part of the event: \Device\RaidPort0."....................................................two years ago, had the same issue and the same error.

The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer. what are you doing?  You should not be posting again until the drive is on its way.  Seriously, you are at risk right now. Also, if it is consistantly occuring even during a clean reboot; you should check the firmware and driver of the array controller and apply updates Go to Solution 3 Comments Do not restart that box.  If you have an amber light on the drive you do NOTHING except get a replacement drive in ASAP.  That lights means "REPLACE ME NOW".  It's

Not 5 minutes ago did i find an HP Advisory about the following two drives: HP 146GB 3G SAS 10K SFF (2.5-inch) Dual Port DG0146BAQPP Hard Drive HP 300GB 3G SAS I wouldn't want to put anything important on there, the danger is that this drive has 'failed' once and it is likely to die the big death at any time. You may be able to use the /AUXSOURCE= flag to retrieve this description; see Help and Support for details. Thanks. 1 person had this problem. 359332.zip ‏9 KB 0 Kudos Reply All Forum Topics Previous Topic Next Topic 4 REPLIES juan quesada Respected Contributor [Founder] Options Mark as New Bookmark

By creating an account, you're agreeing to our Terms of Use, Privacy Policy and to receive emails from Spiceworks. http://ismymailsecure.com/post-error/post-error-1792-drive.html Want to take bets on which array is wiped and which is rebuilt? Email Reset Password Cancel Need to recover your Spiceworks IT Desktop password? Get 1:1 Help Now Advertise Here Enjoyed your answer?

Community ProLiant Servers (ML,DL,SL) CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as Comment Submit Your Comment By clicking you are agreeing to Experts Exchange's Terms of Use. Again, since this disk that I am replacing is on a second datastore and in a separate array from the drives that actually run VMs I can just hot swap the weblink Logical drive number 1 on the array controller in Slot 0 has a new status of 5. (Logical Drive status values: 1=other, 2=ok, 3=failed, 4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding, 8=wrongDrive, 9=badConnect, 10=overheating,

Audible Beeps: None Possible Cause: Power was interrupted while data was in the array accelerator memory. Check does server had a power outage?This message will appear that means the data is the in memory of your raid card waiting to be writen on thedisk.2nd issue is with you have an old drive and you shut down and swap it as a replacement for a failed drive. It SHOULD not bring the array offline and instead give a drive bay

Am I still at risk?  I am definitely not going to restart the server until I replace the drive, but I have already escalated this issue.  1-5 can't be as RAID

what are you doing?  You should not be posting again until the drive is on its way.  Seriously, you are at risk right now. 0 Chipotle OP Daniel83 And that's why the HP docs says to swap a failed hotswappable drive while the system is running. If you have any questions, then please Write a Comment below! Join our community for more solutions or to ask questions.

Experts Exchange Advertise Here 737 members asked questions and received personalized solutions in the past 7 days. Is there an easy way to review the ACU Diag Report attached? This message means that data is the in memory of your raid card waiting to be writen to disk. 0 LVL 3 Overall: Level 3 Message Accepted Solution by:SUSQ2010-12-24 It check over here If it comes up bad then replace, if it comes up OK then I would try and push it back online.

One or more Power-On-Self-Test errors were detected during server startup. [SNMP TRAP: 6027 in CPQHLTH.MIB] I have checked all the disks in HP System Management and none are show any faults you are over 3 yeard behind...this will improve monitoring,stability on the drivesNext, update driver and software for the storage subsystem (controller driver and ACU version) for better recognition of the new I understand this is old but there is really bad advise here regarding swapping the drives. Promoted by Recorded Future Threat intelligence is often discussed, but rarely understood.

Especially likely if bad drive #1 fails and 2 and 3 have to do ALL the work. 0 Serrano OP Justin2100 Jul 21, 2010 at 11:12 UTC Luckily, Suggested Solutions Title # Comments Views Activity SBS 2011 Reports / Alerts / Security Critical 12 69 58d HP Systems Insight Manager installer detected an unsupported operating system 3 109 72d If it's not critical or not production then I have in the past (with good backups) gone into the RAID manager and forced the drive back online and it has worked.